『Beijing Jiubo flowmeter』Related information(clamp on meter|electromagnetic meter|venturi meterrotameter|orifice meter|ultrasonic flow meter|mass flow meter|coriolis mass flow meter|coriolis flow meter|magnetic flow meter|magmeter flow meter|magflow flow meter|mag meter flow meter|electromagnetic flow meter|vortex flow meter|turbine flow meter|thermal mass flow meter|thermal flow meter|rotameter flow meter)

1. The nine wave flowmeter has records but does not display data
If the nine wave flowmeter has records but does not display data, it is usually due to a fault in the sensor signal processing link or display unit, and the signal transmission link and display module power supply need to be checked. 1. Problem diagnosis steps: ① Signal transmission inspection • Check whether the wiring between the sensor and the display instrument is loose or corroded, with a focus on whether the shielding wire grounding is reliable • Use a multimeter to measure the voltage/current value of the signal output terminal: 4-20mA output corresponds to 4mA (0 flow) and 20mA (full range) standards, and pulse output needs to be detected with a frequency meter • If the signal is normal but not displayed, the fault point is in the display unit ② Display unit detection • Confirm the power supply voltage of the display screen (usually 24VDC ± 10%), and if it is lower than 21V, it may trigger undervoltage protection • Check whether the mainboard fuse (usually 0.5A-1A) is blown • Try to restore the factory settings: simultaneously press and hold the "SET"+">" keys for 10 seconds (specific combination needs to refer to the model manual). 2. The sentence is: Common causes of malfunctions • Sensor probe scaling leading to signal attenuation (commonly seen in sewage measurement) • Main board AD conversion module damaged base combustion dust (requiring factory repair) • Display backlight malfunction (weak data visibl

2. What are the recommended manufacturers for flow meters?
3. What should I do if there is no signal for the calibration and echo of the Beijing Jiubo open channel flowmeter?
1. Firstly, there is a fault in the open face of the source rock of the connecting cable (excitation circuit, signal circuit) system.. Check whether the cables connecting the excitation system and signal system are connected and correctly connected.
2、 Secondly, power supply failures such as not being connected. Firstly, confirm that the power supply has been connected, and then check all parts of the power supply. Check the main power supply and excitation current fuse during the hail season. If the current meets the specified value and the new fuse is reconnected but melts, the fault location must be identified. Check if the output voltages of the power circuit board are normal, or replace the entire power circuit board.

Hot News
Related AD
